| NYC Department of Buildings | ||
| Electrical Application Details for App #: A285857 | ||
| Premises: 41-18 27 STREET QUEENS | BIN: 4597153 Block: 415 Lot: 30 |
| Filed: | 41-18 27TH ST | Census Tract: 27 | Health Area: 0720 | |
| ENTIRE BUILDING | Admin Area: A - QUEENS | Inspection Area: C | ||
| QUEENS, NY 11101 | Community Board: 401 | |||
| Related Job Number: 402547712 | |||
| DOB Cross Street(s): 41 AVENUE, QUEENS PLAZA NORTH | |||
| Status: K - CLOSED/CANCELLED 10/07/2014 | |||
| Request Type: A - APPLICATION | eFiled: YES | Permit Issued: 05/04/2010 4:06 PM | |
| Application Entered: 05/04/2010 | Job Start Date: 05/04/2010 | ||
| Last Change: 10/07/2014 | Job End Date: 06/05/2011 | ||
| Appointment Status: | |||
| Last Inspection By: SAMARAS TASOS On 10/01/2014 | |||
| Field Disp: K - OK TO CANCEL | |||
| Energize Recommendation: | |||
| Objection Disposition: | |||
| License #: | 010535 | Licensee Name: | LASZLO FRIEDMAN | |
| Firm: | 003238 | Firm Name: | MAJOR ELECTRIC INC. | |
| Firm Phone: | 718-361-1133 | Firm Address: | 56-32 59TH STREET MASPETH NY 11378 | |
| Work Started or Filed by Others: YES | ||||||||
| Work Category: N - NEW BUILDING | Work To Be Done:
1 - SERVICE WORK/NOTIFY UTILITY 6 - GENERAL WIRING 8 - BOILER/BURNER WIRING |
Total Fee: $1,129.50 | ||||||
| Other Work: | ||||||||
| Work Related to a New or Amended Certificate of Occupancy: YES | ||||||||
| This Job Regulated by the NYC Energy Conservation Code: | ||||||||
| Building Used As: L - Five Or More Family | |||||||
| Special Cert Approval: | |||||||
| Advisory Board Approval: NOT APPLICABLE | |||||||
| Owner / Occup: | MITCHELL HIRTH | ||||||
| Owner Business Name: | 41-18 27TH STREET LLC | ||||||
| Authorized Representative: | |||||||
| Relationship To Owner: | |||||||
|
|
| Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
| Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
| ATT | A/C | |||||||||||
| CEL | 12 | 10 | 10 | |||||||||
| 001 | A,B | 10 | 30 | 4 | 12 | |||||||
| 002 | A,B | 10 | 30 | 4 | 12 | |||||||
| 003 | A,B | 10 | 30 | 4 | 12 | |||||||
| 004 | A,B | 10 | 30 | 4 | 12 | |||||||
| 005 | A,B | 10 | 30 | 4 | 12 | |||||||
| 006 | A,B | 10 | 30 | 4 | 12 | |||||||
| 007 | A,B | 10 | 30 | 4 | 12 | |||||||
| 008 | A,B | 10 | 30 | 4 | 12 | |||||||
| 009 | 5 | 10 | 5 | |||||||||
| ROF | 4 | 2 | 2 | |||||||||
| Buildings Total | 101 | 262 | 32 | 113 | ||||||||
| Total Units : 508 units | ||||||||||||
| Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: | ||
| Meter Request to Utility | #3-Wire | 14 | #4-Wire | 0 | #10-Wire | 1 | |
| Existing Meters | 0 | + New Meters | 15 | - Removed Meters | 0 | = Total Meters | 15 |
| Power Auth Flag: | I - ISSUED | Objection Flag: | |
| Power Requested: | 05/04/2010 | Notice: | |
| Power Issued: | 05/04/2010 | Response: |
| Follow-Up: | K - (CLOSED) | ||
| Contractor's Comments: | |||
|
|
| INSP ID |
FIELD DATE |
DISP DATE |
INSP ID |
FLD DISP |
OBJ DISP |
ENRG REC |
TIME INSP |
REINSP DATE |
NEW OBJ |
APPT FLAG |
| (1) | 10/01/2014 | 10/07/2014 | TS1 | K | (20) | (0) | Y | |||
| INSPECTION COMMENTS: | SEE APPLICATION #A318948 | |||||||||