BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A285590
Premises: 28-18 ASTORIA BOULEVARD QUEENS BIN: 4617229     Block: 596   Lot: 45
   

Filed: 28-18 ASTORIA BLVD Census Tract:   69 Health Area:  0300
BASEMENT,1, 2 ,3,4,5,6,7 FLOOR Admin Area:   A - QUEENS Inspection Area:   A
QUEENS, NY 11102 Community Board:   401
Special Place Name:   NEW BUILDING
Related Job Number:    402604669
DOB Cross Street(s):    28 STREET,    29 STREET
Status:   K - CLOSED/CANCELLED 07/09/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/23/2010 1:32 PM
Application Entered:   04/23/2010 Job Start Date:   04/23/2010
Last Change:   07/09/2014 Job End Date:   04/23/2012
Appointment Status:   
Last Inspection By:   WONG, K.       On     07/09/2014      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 011854 Licensee Name: GEORGE DIAKOUMAKOS
Firm: 003459 Firm Name: E AND G ELEC'L CONTR'G CO
Firm Phone: 718-238-5351  Firm Address: 3904 3RD AVENUE BROOKLYN NY 11232 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
6 - GENERAL WIRING
Total Fee:  $1,935.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: CHARALABOS BAKALIS
Owner Business Name: 28-20 ASTORIA BLVD LLC
Authorized Representative:  CHARALABOS BAKALIS
Relationship To Owner:   OWNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  1  1200 AMPS 3 PHASE
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  28  3 # 6
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  3-SETS 500 MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  28  APARTMENT PANELS 20-1
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  30 CIRCUITS
D. 3 Phase Over 225 AMPS  1  42 CIRCUITS
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  1  200 AMPS
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS  35  25    15  35             
001  63  90  36  63         
002  70  90  36  70         
003  70  90  36  70         
004  67  92  36  67         
005  67  92  36  67         
006  67  92  36  67         
007  70  92  36  70         
Buildings Total 509  663  28  267  509          56      
Total Units : 2032 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 28 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 29 - Removed Meters 0 = Total Meters 29

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 04/23/2010 Notice:  
Power Issued: 04/23/2010 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  NEW BUILDING OF 28 APARTMENTS. 1200 AMPS 3 PHASE SERVICE COMPLETE WIRING POWER AND LIGHTING

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A285590
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/09/2014 07/09/2014 KIW K (1) (0) Y
INSPECTION COMMENTS: SEE APPLICATION#A324870




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back