BIS Menu  |  Property Profile  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A255578
Premises: 11-15 49 AVENUE QUEENS BIN: 4536917     Block: 61   Lot: 80
   
Application Completed and Certified

Filed: 48-15 11 ST Census Tract:   7 Health Area:  0720
NONE Admin Area:   A - QUEENS Inspection Area:   C
QUEENS, NY 11101 Community Board:   402
Related Job Number:    402437065
DOB Cross Street(s):   JACKSON AVENUE,    49 AVENUE
Status:   C - JOB IS SIGNED OFF 06/02/2009
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   03/19/2007 Job Start Date:   05/20/2007
Last Change:   06/02/2009 Job End Date:   01/15/2008
Appointment Status:   
Last Inspection By:   THEODORE JUNSCH       On     05/28/2009      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010036 Licensee Name: GERALD A OTTEN
Firm: 001107 Firm Name: DOBS ELEVATOR COMPANY
Firm Phone: 917-339-9600  Firm Address: 1 PENN PLAZ 250 W. 34TH STREET STE410 NEW YORK NY 10119 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
Total Fee:  $456.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: SCOTT HILL
Owner Business Name: 11-49 REALTY LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  2  
B. Each Additional 10 Floors Or Less  2  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  FURNISH AND INSTALL TWO NEW GEN2 ELEVATORS CONTRACT# 732873-874

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A255578
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/09/2009 02/17/2009 TJ1 J (45) (0) Y
INSPECTION COMMENTS: NONE
 
(2) 04/07/2009 04/14/2009 TJ1 J (45) (0) Y
INSPECTION COMMENTS: NONE
 
(3) 05/28/2009 06/02/2009 TJ1 C (60) (0) Y
INSPECTION COMMENTS: CERTIFICATE