BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A250578
Premises: 15-29 149 STREET QUEENS BIN: 4105671     Block: 4663   Lot: 2
   
Application Completed and Certified

Filed: 15-29 149 ST Census Tract:   1039 Health Area:  0222
1ST FLOOR Admin Area:   A - QUEENS Inspection Area:   B
QUEENS, NY 11357 Community Board:   407
DOB Cross Street(s):    15 ROAD,    15 DRIVE
Status:   C - JOB IS SIGNED OFF 07/16/2007
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/03/2006 2:59 PM
Application Entered:   10/03/2006 Job Start Date:   10/10/2006
Last Change:   07/16/2007 Job End Date:   11/10/2006
Appointment Status:   
Last Inspection By:   BOTSCH, E       On     03/28/2007      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011290 Licensee Name: JAMES FILARDI
Firm: 002857 Firm Name: CROSS HUDSON ELEC'L INC.
Firm Phone: 718-347-3536  Firm Address: 240-21 BRADDOCK AVENUE BELLEROSE NY 11426 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $51.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   THERAPY
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ANGELO IUNILLO
Owner Business Name: THERAPY VILLAGE
Authorized Representative:  ELIZABETH SKINNER
Relationship To Owner:   TENANT


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total   20    15  20                
Total Units : 55 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  INSTALL LIGHTS, SWITCHES, OUTLETS.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A250578
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/28/2007 04/03/2007 EBT C (30) (0) Y
INSPECTION COMMENTS: NONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back