Electrical Application Details for App #: A178027
Premises: 42-75 MAIN STREET QUEENS BIN: 4115885     Block: 5136   Lot: 73
   
Application Completed and Certified

Filed: 42-75 MAIN ST Census Tract:   797 Health Area:  1200
135748 BASEMENT Admin Area:   A - QUEENS Inspection Area:   B
QUEENS, NY 11355 Community Board:   407
DOB Cross Street(s):   BLOSSOM AVENUE,    CHERRY AVENUE
Status:   C - JOB IS SIGNED OFF 08/06/2001
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   03/13/2001 Job Start Date:   03/01/2001
Last Change:   07/30/2001 Job End Date:   04/01/2001
Appointment Status:   
Last Inspection By:   GALIZIA, J.       On     07/24/2001      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 011396 Licensee Name: SPIRO VALENTIS
Firm: 002831 Firm Name: VALENTIS ELECTRIC, INC.
Firm Phone: 718-726-0072  Firm Address: 32-21 58TH STREET WOODSIDE NY 11377 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $96.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   DELI
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: ALLEN LOOK
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 10  10    27                
Total Units : 54 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 03/13/2001 Notice:  
Power Issued: 03/13/2001 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  ASE SERVICE 200AMPS FOR DELI

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A178027
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/20/2001 07/30/2001 JG1 Z (0) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 07/24/2001 07/30/2001 JG1 C E (45) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application