BIS Menu  |  After Hours Variance Permit Data  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A151130
Premises: 60-15 FRESH POND ROAD QUEENS BIN: 4061621     Block: 2757   Lot: 1
   
Application Completed and Certified

Filed: 60-15 FRESH POND RD Census Tract:   599 Health Area:  1700
NONE Admin Area:   A - QUEENS Inspection Area:   G
QUEENS, NY 11378 Community Board:   405
DOB Cross Street(s):    60 AVENUE,    60 ROAD
Status:   C - JOB IS SIGNED OFF 12/29/1998
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   09/22/1998 Job Start Date:   09/18/1998
Last Change:   12/24/1998 Job End Date:   12/31/1998
Appointment Status:   
Last Inspection By:   ASHMAN, K.       On     12/12/1998      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 008969 Licensee Name: HENRY MOSES
Firm: 000090 Firm Name: ALCO ELEC. CO., INC.
Firm Phone: 718-884-0600  Firm Address: 5790 BROADWAY BRONX NY 10463 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $25.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: H. MARGOLIES
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 2 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/22/1998 Notice:  
Power Issued: 09/22/1998 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: ADDING 1-MTR FOR SUPER'S APT, & 1 FOR FUTURE. NOT CONNECTG ANY LOADS
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A151130
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/12/1998 12/24/1998 KAS C E (15) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application