BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A114025
Premises: 59-06 LAUREL HILL BOULEVARD QUEENS BIN: 4054168     Block: 2344   Lot: 30
   
Application Completed and Certified

Filed: 50-16 59 PL Census Tract:   243 Health Area:  0920
NONE Admin Area:   A - QUEENS Inspection Area:   C
QUEENS, NY 11377 Community Board:   402
DOB Cross Street(s):    50 AVENUE,    TYLER AVENUE
Status:   C - JOB IS SIGNED OFF 02/03/2005
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   05/16/1995 Job Start Date:   05/03/1995
Last Change:   02/03/2005 Job End Date:   07/01/1995
Appointment Status:   
Last Inspection By:   GALIZIA, J.       On     02/02/2005      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010114 Licensee Name: RICHARD ADDEO
Firm: 000064 Firm Name: ADCO ELEC'L CORP
Firm Phone: 718-494-4400  Firm Address: 201 EDWARD CURRY AVENUE STATEN ISLAND NY 10314 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $747.50
Other Work:   7
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   NYPD 911 SITE
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: NYPD
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  3  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  4  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 24  63  18  24              
Total Units : 144 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 10/03/2003
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A114025
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/11/1997 08/04/1997 RJM Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 10/14/1997 10/18/1997 KAM V G (60) (1)
INSPECTION COMMENTS: GRDING RACEWAY NOT CONTINOUS TO LUG 27-3110C
 
(3) 07/18/2003 07/29/2003 JG1 Z (0) (0) Y
INSPECTION COMMENTS: APPT CONTRACTOR NO SHOW
 
(4) 07/21/2003 07/29/2003 JG1 L (60) (0) Y
INSPECTION COMMENTS: COULD NOT LOCATE NEW 1195 GENERATOR LOCATION PROBLEM
 
(5) 09/30/2003 10/03/2003 JG1 V R (80) (2) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 07/07/2004 07/09/2004 JG1 J Y (65) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 02/02/2005 02/03/2005 JG1 C R E (105) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back