BIS Menu  |  Property Profile  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: A073097
Premises: 29-29 DITMARS BOULEVARD QUEENS BIN: 4017713     Block: 846   Lot: 67
   
Application Completed and Certified

Filed: 29-29 DITMARS BLVD Census Tract:   113 Health Area:  0120
LAMPPOST Admin Area:   A - QUEENS Inspection Area:   A
QUEENS, NY 11105 Community Board:   401
DOB Cross Street(s):    29 STREET,    31 STREET
Status:   C - JOB IS SIGNED OFF 07/13/1993
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   12/04/1991 Job Start Date:   11/25/1991
Last Change:   07/13/1993 Job End Date:   12/31/1991
Appointment Status:   
Last Inspection By:   MURRAY, R. J.       On     07/09/1993      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 010610 Licensee Name: RICHARD NANNETTI
Firm: 002233 Firm Name: JOHN CAPPELLI ELEC'L INST
Firm Phone: 718-378-0100  Firm Address: 400 BARETTO STREET 1NC. BRONX NY 10474 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
9 - OTHER
Total Fee:  $33.00
Other Work:   CHRISTMAS LIGHT
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   STREET XMAS LITE
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: JOHN CAPPELLI ELECT CONTR
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                     
Total Units : 8 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   MON - FRI 9-3:30 PM Contact Phone:   212-589-9292

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Wires Comments: TEMP CHRISTMAS LIGHTING
Contractor's Comments:  CHRISTMAS LIGHTS FROM LAMPPOST

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A073097
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/31/1991 01/06/1992 RJM J G (15) (0)
INSPECTION COMMENTS: TEMP XMAS LITES
 
(2) 07/09/1993 07/13/1993 RJM C G (10) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application