Premises: 37-38 WARREN STREET QUEENS BIN: 4036604     Block: 1483   Lot: 26
   
Application Completed and Certified

Filed: 37-38 WARREN ST Census Tract:   273 Health Area:  1012
BASEMENT Admin Area:   A - QUEENS Inspection Area:   D
QUEENS, NY 11372 Community Board:   403
DOB Cross Street(s):    37 AVENUE,    ROOSEVELT AVENUE
Status:   C - JOB IS SIGNED OFF 05/08/1992
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   09/07/1989 Job Start Date:   08/31/1989
Last Change:   05/01/1992 Job End Date:   08/31/1989
Appointment Status:   
Last Inspection By:   WILSON, J.       On     04/23/1992      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 009976 Licensee Name: NICK M TARASIS
Firm: 001411 Firm Name: TARASIS ELECTRIC CORP.
Firm Phone: 718-937-5800  Firm Address: 45-48 51ST STREET WOODSIDE NY 11377 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $29.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   A - One Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: G.BAKALID
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   ANYTIME Contact Phone:   718 886 5791

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 2 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/07/1989 Notice:  
Power Issued: 09/07/1989 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: A045338
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/02/1990 02/23/1990 SKR Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 05/11/1990 06/01/1990 SKR Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 06/22/1990 07/10/1990 SKR Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 08/03/1990 08/28/1990 SKR Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 10/09/1990 10/26/1990 SKR N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 04/23/1992 05/01/1992 JW1 C E (35) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application