Electrical Application Details for App #: 047629
Premises: 184 CLAREMONT AVENUE MANHATTAN BIN: 1059864     Block: 1993   Lot: 107
   
Application Completed and Certified

Filed: 184 CLAREMONT AV Census Tract:   211 Health Area:  1400
BASEMENT Admin Area:   Z - UPPER MANHATTAN Inspection Area:   C
NEW YORK, NY 10027 Community Board:   109
DOB Cross Street(s):   LA SALLE STREET,    TIEMANN PLACE
Status:   C - JOB IS SIGNED OFF 08/13/1987
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   03/05/1986 Job Start Date:   11/20/1985
Last Change:   08/13/1987 Job End Date:   11/20/1985
Appointment Status:   
Last Inspection By:   BOARD, K.       On     07/31/1987      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010051 Licensee Name: G MODICA
Firm: 001016 Firm Name: MODICA & REILLY ELEC'L CR
Firm Phone: 718-256-2020  Firm Address: 1613 63RD STREET BROOKLYN NY 11204 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
5 - FIRE DAMAGE
Total Fee:  $17.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: CLAREMONT ASSOC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Wires Comments: TO WIRE OIL BURNER WITH RESET PRESSURETROL
Contractor's Comments:  E 1200

 
Inspection Details
 

INSPECTION FOR APPLICATION #: 047629
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 06/12/1987 06/30/1987 AG1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 07/31/1987 08/13/1987 KCB C (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application