| BUILDING OVERVIEW |
Are Feeders Being Installed? : |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
0 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
INSP ID |
FIELD DATE |
DISP DATE |
INSP ID |
FLD DISP |
OBJ DISP |
ENRG REC |
TIME INSP |
REINSP DATE |
NEW OBJ |
APPT FLAG |
| |
| (1) |
02/26/1986 |
|
DH2 |
A |
R |
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (2) |
05/14/1986 |
05/23/1986 |
DH2 |
A |
R |
G |
(30) |
|
(2) |
|
| INSPECTION COMMENTS:
|
NEUTRAL NOT BONDED 3/400A SERVICE SWITCH TO ENCLOSURE
|
| |
| (3) |
08/20/1986 |
08/25/1986 |
DH2 |
H |
|
E |
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (4) |
11/28/1986 |
12/22/1986 |
DH2 |
Z |
|
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (5) |
02/24/1987 |
02/27/1987 |
DH2 |
H |
X |
E |
(15) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (7) |
06/12/1987 |
06/30/1987 |
DH2 |
Z |
|
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (8) |
07/24/1987 |
08/17/1987 |
DH2 |
Z |
|
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (9) |
09/18/1987 |
10/08/1987 |
DH2 |
Z |
|
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (10) |
10/30/1987 |
11/30/1987 |
PB1 |
Z |
|
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (11) |
12/11/1987 |
01/15/1988 |
PB1 |
Z |
|
|
(0) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (12) |
04/15/1988 |
05/09/1988 |
GO1 |
Z |
|
|
(5) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (13) |
08/16/1988 |
08/18/1988 |
GO1 |
H |
X |
G |
(20) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (15) |
05/08/1989 |
05/16/1989 |
GO1 |
H |
X |
B |
(60) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (16) |
03/28/2003 |
04/22/2003 |
PAT |
Z |
|
|
(0) |
|
(0) |
Y |
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|