BIS Menu  |  Property Profile  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M377127
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 60 WEST 37 STREET MANHATTAN BIN: 1090374     Block: 838   Lot: 10
   

DOB NOW: Inspections


Filed: 60 W37 ST Census Tract:   84 Health Area:  5200
ALL FLOORS Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10018 Community Board:   105
Related Job Number:    121235029
DOB Cross Street(s):    5 AVENUE,    AVENUE OF THE AMERICAS
Status:   K - CLOSED/CANCELLED 05/16/2019
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  01/22/2016 6:28 AM
Application Entered:   01/22/2016 Job Start Date:   01/22/2016
Last Change:   05/16/2019 Job End Date:   01/05/2017
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   ALGERNON CHARLES       On     05/16/2019      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 011437 Licensee Name: ANTONY GIRONTA
Firm: 002894 Firm Name: AGIR ELEC'L LTD. D/B/A
Firm Phone: 718-846-6200  Firm Address: 130-45 91ST AVENUE PINNACLE ELECTRICAL RICHMOND HILL NY 11418 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $3,468.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   H - Hotel
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: PETER SERPICO
Owner Business Name: CAVA CONSTRUCTION INC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  1  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  25  
D. 3 Phase Over 225 AMPS  10  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    20  25  15               
001    30  25  15               
002    30  45  10  20               
004    30  45  10  20               
005    30  45  10  20               
006    30  45  10  20               
007    30  45  10  20               
008    30  45  10  20               
009    30  45  10  20               
010    30  45  10  20               
011    30  45  10  20               
012    30  45  10  20               
013    30  45  10  20               
014    30  45  10  20               
015    30  45  10  20               
016    30  45  10  20               
017    30  45  10  20               
018    30  45  10  20               
019    30  45  10  20               
020    30  45  10  20               
021    30  45  10  20               
022    30  45  10  20               
023    30  45  10  20               
024    30  45  10  20               
025    30  45  10  20               
026    30  45  10  20               
027    30  45  10  20               
028    28  45  10  20               
029    30  45  10  20               
030    30  45  10  20               
031    30  45  10  20               
032    30  45  10  20               
033    30  45  10  20               
034    30  45  10  20               
035    30  45  10  20               
036    30  45  10  20               
037    30  45  10  20               
038    15  20  10               
039    15  20  10               
ROF    10  10               
Buildings Total 1138  1675  357  755                  
Total Units : 3925 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 2
Existing Meters 0 + New Meters 2 - Removed Meters 0 = Total Meters 2

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 01/22/2016 Notice:  
Power Issued: 01/22/2016 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  WIRE FOR LIGHTS AND POWER

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: M377127
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/09/2018 10/09/2018 MJD J (10) (0) Y
INSPECTION COMMENTS: FAIL, JOB IN PROGRESS SEE APPLICATION #M395392
 
(2) 03/15/2019 03/15/2019 PMK I (11) (0) Y
INSPECTION COMMENTS: FAIL
 
(3) 05/16/2019 05/16/2019 AYC K (45) (0) Y
INSPECTION COMMENTS: PASS. APPLICATION SUPERSEDED BY APP. M395392.




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Property Profile  |  Electrical Inspection Work Order  |  Back