Electrical Application Details for App #: A367443
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 30-02 48 AVENUE QUEENS BIN: 4003546     Block: 287   Lot: 11
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 30-02 48 AV Census Tract:   199
1ST FLOOR Admin Area:   A - QUEENS Inspection Area:   C
QUEENS, NY 11101 Community Board:   402
Special Place Name:   BINDERY
DOB Cross Street(s):    30 STREET,    30 PLACE
Status:   C - JOB IS SIGNED OFF 06/26/2019
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   09/26/2017 Job Start Date:   09/27/2017
Last Change:   06/26/2019 Job End Date:   09/28/2018
Appointment Status:   
Last Inspection By:   BASDEO, C       On     06/26/2019      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 012196 Licensee Name: ANTHONY NOLAN
Firm: 003904 Firm Name: ALLCOM ELECTRIC CORP
Firm Phone: 718-402-2481  Firm Address: 243 EAST 138TH STREET BRONX NY 10451 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $1,465.00
Hurricane Sandy Damage:   No
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   REQUIRED
Advisory Board Categories:      K - 1000 KVA SERVICE                            
Advisory Board Approval #:   54725     Submittal #: 17A0073  
Owner / Occup:
Owner Business Name: BRICKMAN REALTY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  600 AS
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  1  4000 AS
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  4/0 AWG
D. Over 250 MCM  12  12 SETS OF 500 KCMIL
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  OTHER FEEDERS & WORK WAS INCLUDED IN APP #A359062 & A365381

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: A367443
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/26/2019 06/26/2019 COB C (94) (0) Y
INSPECTION COMMENTS: INSPECTION OK