Electrical Application Details for App #: B381447
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 360 MONROE STREET BROOKLYN BIN: 3322346     Block: 1820   Lot: 9
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 360 MONROE ST Census Tract:   265 Health Area:  2000
BASEMENT, 1ST, 2ND & 3RD FLOOR Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11221 Community Board:   303
DOB Cross Street(s):   TOMPKINS AVENUE,    THROOP AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/25/2014 5:28 PM
Application Entered:   05/25/2014 Job Start Date:   05/25/2014
Last Change:   08/22/2025 Job End Date:   05/03/2015
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   CHARLES COURTNEY       On     12/11/2014      
Field Disp:   A - OBJCTN ISSD: JOB COMPLETE
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011783 Licensee Name: DARRYL STOVALL
Firm: 003394 Firm Name: D & S ELECTRICAL CORP.
Firm Phone: 718-869-5460  Firm Address: 450 BEACH 48TH STREET,LOT FAR ROCKAWAY NY 11691 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $163.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (1  Stores, 2 Apartments)
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: DOREEN DELEON
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  3  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS                 
GND                   
001                 
002    14  10  14             
003    14  10  14             
Buildings Total 43  27  40                
Total Units : 120 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 12/15/2014 Notice: 1 - FIRST NOTICE 12/15/2014
Power Issued: 12/15/2014 Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: B381447
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/14/2014 10/21/2014 PAT J (65) (0) Y
INSPECTION COMMENTS: ENTIRE JOB NOT COMPLETED
 
(2) 11/07/2014 11/10/2014 DAH A (65) (5) Y
INSPECTION COMMENTS: N
 
(3) 12/11/2014 12/15/2014 CCH A R E (45) (2) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B381447
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
PNL NEUTRAL BONDED AFTER SVC PNL ARTICLE 250.24 (B)
RSLV 11/07/2014 11/07/2014 12/11/2014
 
002 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
UNAPPROVE LAMP FIXTURER REAR CLOSET
RSLV 11/07/2014 11/07/2014 12/11/2014
 
003 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
UNAPPROVE LAMP FIXTURE REAR CLTHES CLOSET
RSLV 11/07/2014 11/07/2014 12/11/2014
 
004 (999) OTHER
INSUFFICIENT OUTLET IN KITCHEN WATER ARTICLE
RSLV 11/07/2014 11/07/2014 12/11/2014
 
005 ( 14) CIRCUIT OVERCURRENT PROTECTION DEVICE IS OF IMPROPER SIZE
FDRS OCER FUSED (2) 100A BKRS
RSLV 11/07/2014 11/07/2014 12/11/2014
 
006 (999) OTHER
PENNSUILA OVER 24 NO OUTLET 2 3 FL 210.52 C3
OPEN 12/11/2014 12/11/2014
 
007 ( 19) DEFECTIVE WIRING IS IN USE
LIGHT UNDER CT WIRE BELLWIRE
OPEN 12/11/2014 12/11/2014