Electrical Application Details for App #: M331878
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 50 PINE STREET MANHATTAN BIN: 1001011     Block: 41   Lot: 7501
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 50 PINE ST Census Tract:   7 Health Area:  7700
1 FLOOR Admin Area:   M - MANHATTAN Inspection Area:   W
NEW YORK, NY 10005 Community Board:   101
Special Place Name:   DUNKIN DONUTS
DOB Cross Street(s):   WILLIAM STREET,    PEARL STREET
Status:   C - JOB IS SIGNED OFF 04/24/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/12/2012 5:40 PM
Application Entered:   09/12/2012 Job Start Date:   09/12/2012
Last Change:   04/24/2017 Job End Date:   01/30/2013
Appointment Status:   
Last Inspection By:   MCPARTLAND, BRIAN       On     04/20/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010804 Licensee Name: SANG CHEUNG
Firm: 002065 Firm Name: AL-LECTRIC ELECT'L CONTRG
Firm Phone: 212-219-3336  Firm Address: 137 CHRYSTIE STREET NEW YORK NY 10002 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $252.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   K - Store
Store / Other:   DUNKIN DONUTS
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: DENNIS FANG
Owner Business Name: D&S BUILDING SERVICE INC.
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  2  2-3/0
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  2  2-200 AMP
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001    30  28    12  30             
Buildings Total 30  28    12  30                
Total Units : 100 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 01/23/2017
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: M331878
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/23/2017 01/23/2017 PHG V (30) (3)
INSPECTION COMMENTS: CONTRACTOR TO FILE FOR ALL WORK DONE HEATERS MOTORS ECT DID NOT INSPECT WORK NOT FILED FOR
 
(2) 04/20/2017 04/21/2017 BMP C R (25) (0)
INSPECTION COMMENTS: OBJECTIONS REMOVED. CERTIFIED.

OBJECTION FOR APPLICATION #: M331878
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
(GROUND FLOOR) 2 NEUTRAL WIRES UNDER 1 LUG IN BOTH PANELS 110.3
RSLV 01/23/2017 01/23/2017 04/20/2017
 
002 ( 40) LOCKNUTS ARE MISSING OR LOOSE
(GROUND FLOOR) LOCK NUTS MISSING IN PANEL FOR PIPES 300.10
RSLV 01/23/2017 01/23/2017 04/20/2017
 
003 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
(OPEN SPACE)EMT PIPE AND 1900 BOX USED OUTSIDE FOR OUTLET BY FRONT DOOR 110.3358.10C
RSLV 01/23/2017 01/23/2017 04/20/2017