Electrical Application Details for App #: B378070
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 1 FULTON STREET BROOKLYN BIN: 3000078     Block: 35   Lot: 12
   
Application Completed and Certified

Filed: 1 OLD FULTON ST Census Tract:   21 Health Area:  1000
GROUND FLOOR Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11201 Community Board:   302
Special Place Name:   SHAKE SHACK
Related Job Number:    320894528
DOB Cross Street(s):   WATER STREET,    EVERIT STREET
Status:   C - JOB IS SIGNED OFF 08/15/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  02/27/2014 11:33 AM
Application Entered:   02/27/2014 Job Start Date:   02/27/2014
Last Change:   08/15/2014 Job End Date:   02/27/2015
Appointment Status:   
Last Inspection By:   JOHN, CHARLES       On     06/05/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010619 Licensee Name: CHAIM MILCHMAN
Firm: 003844 Firm Name: M & M CONTROL WIRING &
Firm Phone: 718-477-5342  Firm Address: 2952 RICHMOND TERRACE ELECTRICAL, INC STATEN ISLAND NY 10303 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
L - LIGHTING WORK
Total Fee:  $585.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   Yes
Job Number:  320894528
Building Used As:   K - Store
Store / Other:   RESTAURANT
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MARK PASCIUTO
Owner Business Name: TRINITY CONST & MGMT
Authorized Representative:  MARK PASCIUTO
Relationship To Owner:   GC


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  3  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  2  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  2  (2) 100A 3P
D. 3 Phase Over 225 AMPS  3  (1) 800A (2) 400A
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL      10    10         
001      20    12  50             
Buildings Total   30    16  60              
Total Units : 112 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 06/09/2014 Notice: 1 - FIRST NOTICE 05/27/2014
Power Issued: 06/09/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: B378070
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/21/2014 05/27/2014 CJE V (60) (6) Y
INSPECTION COMMENTS: N
 
(2) 06/05/2014 06/09/2014 CJH C R E (35) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B378070
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 53) GFCI HAS NOT BEEN PROVIDED
RECEPTACLE IN FOOD PREPARATION AREA NOT GFCI PROTECTED 210.8(2)
RSLV 05/21/2014 05/21/2014 06/05/2014
 
002 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
KNOCKOUT SEALS MISSING IN PANEL ART 110.12(A)
RSLV 05/21/2014 05/21/2014 06/05/2014
 
003 ( 33) KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX
KNOCKOUT SEAL MISSING FOR JB IN CEILING ART 110.12(A)
RSLV 05/21/2014 05/21/2014 06/05/2014
 
004 (999) OTHER
NO GROUND CONDUCTOR FOR TRACK LIGHTS ART 410.46
RSLV 05/21/2014 05/21/2014 06/05/2014
 
005 (999) OTHER
COVER PLATES MISSING FOR RECEPTACLE ART 406.5
RSLV 05/21/2014 05/21/2014 06/05/2014
 
006 ( 24) ARMORED CABLES ARE NOT PROPERLY SECURED
ARMORED CABLE HANGING FROM CEILING 320.30
RSLV 05/21/2014 05/21/2014 06/05/2014