Electrical Application Details for App #: B062368
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 966 CONEY ISLAND AVENUE BROOKLYN BIN: 3127969     Block: 5425   Lot: 32
   

Filed: 966 CONEY ISLAND AV Census Tract:   482 Health Area:  7000
NONE Admin Area:   B - BROOKLYN Inspection Area:   K
BROOKLYN, NY 11230 Community Board:   314
DOB Cross Street(s):   WEBSTER AVENUE,    NEWKIRK AVENUE
Status:   C - COMPLETED
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/22/1990 Job Start Date:   01/09/1990
Last Change:   03/22/1990 Job End Date:   01/12/1990
Appointment Status:   
Last Inspection By:   COEN, MICHAEL       On     03/09/1990      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010732 Licensee Name: RICHARD F BROWN
Firm: 001740 Firm Name: TRIAC ELECTRICAL CORP.
Firm Phone: 718-492-8050  Firm Address: 966 CONEY ISLAND AVENUE BROOKLYN NY 11230 

Work Started or Filed by Others: NO
Work Category:   S - SHOP INSPECTION Work To Be Done:   Total Fee:  $0.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   SIGN MAKER
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: DAVID SIGNS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Sign Dimensions : 4 Ft 0 In  BY  20 Ft 0 In  Total Sq. Ft. of Sign: 80
Sign Type :
Total Circuits: 1 Total Lamps: 8
Watts (Lamps): 0 Number of Trans: 2 VA of Each Trans: 0
Total Watts or VA: 1056 A.W. Gauge of Wire: 14 No. of Sockets Per Circuit: 8
Material/Gauge: ALUM CONSTR
Sign Maker : DAVID SIGNS
Sign Maker Address: 966 CONEY ISLAND AVE,BROOKLYN NY 11230
Shop Address:
Shop Phone:
Shop Location Comments:
Sign Text: DAVIS

Access:   9AM TO 6PM MON TO FRI Contact Phone:   853 0781

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: B062368
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/09/1990 03/22/1990 MC1 C (45) (0)
INSPECTION COMMENTS: NONE




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.