BIS Menu  |  Comments  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M376553
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 300 EAST 64 STREET MANHATTAN BIN: 1044388     Block: 1438   Lot: 7502
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 300 E 64TH ST Census Tract:   110 Health Area:  4900
APT 8A AND 8D Admin Area:   M - MANHATTAN Inspection Area:   M
NEW YORK, NY 10065 Community Board:   108
DOB Cross Street(s):    2 AVENUE,    1 AVENUE
Status:   C - JOB IS SIGNED OFF 03/28/2016
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  01/06/2016 5:58 PM
Application Entered:   01/06/2016 Job Start Date:   01/07/2016
Last Change:   03/28/2016 Job End Date:   06/20/2016
Appointment Status:   
Last Inspection By:   MOSES, DANIEM       On     03/28/2016      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012234 Licensee Name: GABRIEL HAIMOVICI
Firm: 003972 Firm Name: MATRIX ELEC'L CONTRG, INC
Firm Phone: 917-832-7032  Firm Address: 35-37 36TH STREET 6TH FLOOR INC ASTORIA NY 11106 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $74.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (30  Stores, 2 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: FRANK SPADAFORA
Owner Business Name: C/O RFR REALTY LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
008    28  37    18               
Buildings Total 28  37    18                  
Total Units : 83 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: C - CALL TO OFFICE 03/16/2016
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: M376553
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/29/2016 02/01/2016 CBK V (45) (6)
INSPECTION COMMENTS: FAILED.
 
(2) 02/12/2016 02/16/2016 CBK N (30) (0) Y
INSPECTION COMMENTS: NO SHOW.
 
(3) 03/15/2016 03/16/2016 STP V X (45) (1)
INSPECTION COMMENTS: JOB WAS INSPECTED ON 3/14/2016. ACCELLA WAS DOWN COULD NOT GET JOB ON OVERTIME.
 
(4) 03/28/2016 03/28/2016 DNM C R (25) (0)
INSPECTION COMMENTS: OBJECTIONS REMOVED.

OBJECTION FOR APPLICATION #: M376553
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 008) CLOSET, OPEN BULB. 410.16 (B)
RSLV 01/29/2016 01/29/2016 03/28/2016
 
002 (999) OTHER
(FLOOR: 008)BATH ROOM NO GFCI RECEPTACLE PROVIDED. T-OUT. 210.52 (5) (D)
RSLV 01/29/2016 01/29/2016 03/28/2016
 
003 (999) OTHER
(FLOOR: 008)KITCHEN, NO GFCI PROVIDED FOR PLUG MOULD. BOTH APARTMENTS. 210.8
RSLV 01/29/2016 01/29/2016 03/28/2016
 
004 (999) OTHER
(FLOOR: 008) KITCHEN, PLUG MOULD NOT OF THE TR TYPE. 406.11
RSLV 01/29/2016 01/29/2016 03/28/2016
 
005 (999) OTHER
(FLOOR: 008)BALCONY ,NO IN USE COVER PROVIDED FOR RECEPTACLES. 406.8
RSLV 01/29/2016 01/29/2016 03/28/2016
 
006 (999) OTHER
(FLOOR: 008) BALCONY, OPEN BOXES. 314.25
RSLV 01/29/2016 01/29/2016 03/28/2016
 
007 (999) OTHER
(FLOOR: 008) BATHROOM GFI NOT T.R T OUT ALL BATHROOMS 406.11
RSLV 03/15/2016 03/15/2016 03/28/2016



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Comments  |  Electrical Inspection Work Order  |  Back