NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 307 SPRING STREET MANHATTAN BIN: 1010364     Block: 597   Lot: 33
   
Application Completed and Certified

Filed: 307 SPRING ST Census Tract:   53 Health Area:  6800
052391 BSMT/1 FL Admin Area:   M - MANHATTAN Inspection Area:   U
NEW YORK, NY 10013 Community Board:   102
DOB Cross Street(s):   RENWICK STREET,    GREENWICH STREET
Status:   C - JOB IS SIGNED OFF 12/09/2003
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   02/20/2002 Job Start Date:   02/11/2002
Last Change:   12/09/2003 Job End Date:   04/25/2002
Appointment Status:   
Last Inspection By:   REDDINGTON, J.       On     10/06/2003      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010407 Licensee Name: GERARD LEIB
Firm: 002431 Firm Name: G.E.O. ELECTRIC CORP
Firm Phone: 718-945-6464  Firm Address: 202-34 ROCKAWAY POINT BLVD. BREEZY POINT NY 11697 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $524.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   RESTAURANT
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: SPRING LELTARD L.L.C
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  2  
D. Over 250 MCM  1  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  2  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  2  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 92  23  26  92              
Total Units : 242 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 9 #10-Wire 1
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 02/20/2002 Notice: 1 - FIRST NOTICE 09/27/2002
Power Issued: 02/20/2002 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: M209172
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/25/2002 09/27/2002 SVJ V G (45) (5)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 07/17/2003 07/28/2003 SVJ N (1) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 10/06/2003 10/14/2003 SR2 C R E (60) (0) Y
INSPECTION COMMENTS: COMP VIOLS