Electrical Application Details for App #: Z086891
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 3 WEST 87 STREET MANHATTAN BIN: 1031463     Block: 1201   Lot: 27
   
Application Completed and Certified

Filed: 3 W 87 ST Census Tract:   173 Health Area:  3220
212 541 4100 BASEMENT Admin Area:   Z - UPPER MANHATTAN Inspection Area:   D
NEW YORK, NY 10024 Community Board:   107
DOB Cross Street(s):   CENTRAL PARK WEST,    COLUMBUS AVENUE
Status:   C - JOB IS SIGNED OFF 06/05/2001
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   04/24/2001 Job Start Date:   05/01/2001
Last Change:   06/05/2001 Job End Date:   07/01/2001
Appointment Status:   
Last Inspection By:   PETER GREENE       On     06/01/2001      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 011089 Licensee Name: PIOTR WAS
Firm: 003040 Firm Name: ACP ELECTRICAL CONTRACTIN
Firm Phone: 212-541-4100  Firm Address: 412 WEST 48TH STREET, STE#1 NEW YORK NY 10036 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
9 - OTHER
Total Fee:  $10.00
Other Work:   REMOVING VIVOL TO OTHER LIC FIRM(Z073681)
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   REQUIRED
Advisory Board Categories:      K - 1000 KVA SERVICE                            
Advisory Board Approval # / Submittal #:   TO FOLLOW
Owner / Occup:
Owner Business Name: CENTRAL PARK WEST REALTY,
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                 
Total Units : 6 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Wires Comments: REMOVAL OF VIOLATION Z073681
Contractor's Comments:  CENTRAL PARK WEST INSTALL BOX COVERS+KO SEALS 163880

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: Z086891
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/01/2001 06/05/2001 PGR C G (75) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application