Electrical Application Details for App #: B327186
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 284 CORBIN PLACE BROOKLYN BIN: 3245745     Block: 8723   Lot: 279
   
Application Completed and Certified

Filed: 286 CORBIN PL Census Tract:   610.02 Health Area:  9120
BASEMENT/BOILER ROOM Admin Area:   B - BROOKLYN Inspection Area:   R
BROOKLYN, NY 11235 Community Board:   315
DOB Cross Street(s):   ORIENTAL BOULEVARD,    DEAD END
Status:   C - JOB IS SIGNED OFF 08/02/2010
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  05/12/2010 11:41 PM
Application Entered:   05/12/2010 Job Start Date:   05/13/2010
Last Change:   08/02/2010 Job End Date:   05/05/2011
Appointment Status:   
Last Inspection By:   COHN, MARTIN       On     07/28/2010      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 009967 Licensee Name: SULPICE CHAMBLIN
Firm: 003265 Firm Name: PS&E ELECTRIC CONTRS INC
Firm Phone: 718-320-9400  Firm Address: 112-08 SPRINGFIELD BLVD QUEENS VILLAGE NY 11429 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
8 - BOILER/BURNER WIRING
Total Fee:  $52.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MEIR BOUSKILLA
Owner Business Name: 286 CORBIN PLACE OWNERS
Authorized Representative:  MEIR BOUSKILLA
Relationship To Owner:   AGENT


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS                     
Buildings Total                       
Total Units : 4 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: B327186
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/28/2010 08/02/2010 MC2 C (30) (0) Y
INSPECTION COMMENTS: N