NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 15 PIERREPONT STREET BROOKLYN BIN: 3001732     Block: 234   Lot: 5
   
Application Completed and Certified

Filed: 15 PIERREPONT ST Census Tract:   3.01 Health Area:  2300
BASEMENT Admin Area:   B - BROOKLYN Inspection Area:   C
BROOKLYN, NY 11201 Community Board:   302
DOB Cross Street(s):   PIERREPONT PLACE,    WILLOW STREET
Status:   C - JOB IS SIGNED OFF 03/16/2015
Request Type:   P - PICK-UP eFiled:   YES
Application Entered:   02/11/2015 Job Start Date:   02/13/2015
Last Change:   03/16/2015 Job End Date:   02/14/2015
Appointment Status:    Complaint Number:    3403480
Last Inspection By:   JOHN, CHARLES       On     03/12/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010874 Licensee Name: ALFONSO GIGANTE
Firm: 002154 Firm Name: A.C.G. ELECT. CO., INC.
Firm Phone: 718-714-7292  Firm Address: 153 MAIN STREET STATEN ISLAND NY 10307 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $200.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (1  Stores, 5 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MARK EGER
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 03/16/2015 Notice: 1 - FIRST NOTICE 03/03/2015
Power Issued: 03/16/2015 Response: F - FILED TO REMOVE OBJECTION 02/11/2015

Follow-Up: X - FILED APPL,NOW CLOSED 02/11/2015
Contractor's Comments:  NONE

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: B356190
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/17/2012 11/14/2012 MC2 W (15) (5)
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(2) 02/24/2015 03/03/2015 CLC A R (30) (1) Y
INSPECTION COMMENTS: NONE
 
(3) 03/12/2015 03/16/2015 CJH C R E (20) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B356190
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 3) APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION NOT ON FILE
NO APP/PERMIT ELECTRICAL WORK IN BASEMENT AT 200 AMP SERVICE SWITCH27.3017A AND 27.3018B, 1 SERVICE EMT, FEEDER 4 3/0
RSLV 10/17/2012 10/17/2012 02/24/2015
 
002 (999) OTHER
BASEMENT IN 200 AMP S/S LOAD SIDE. DOUBLE LUGGED 110.14A
RSLV 10/17/2012 10/17/2012 02/24/2015
 
003 (999) OTHER
BASEMENT DEFECTIVE WIRING BRIDGE CONNECTION CAUSING OVER LOADEDNEUTRAL CONDUCTORS, TWO OF 3 UNGROUNDED CONDUCTORS ALL SAME PHASE
RSLV 10/17/2012 10/17/2012 02/24/2015
 
004 (999) OTHER
300.13B
RSLV 10/17/2012 10/17/2012 02/24/2015
 
005 (999) OTHER
BASEMENT S/S NOT IDENTIFIED AS MUCH. 230.72ANOT FINAL INSPECTION. REF #3403480
RSLV 10/17/2012 10/17/2012 02/24/2015
 
006 ( 15) FLEXIBLE CORDS USED AS PERMANENT WIRING METHOD
200AMP SVC SW 2/0 WIRE FUSED AT 200AMP
RSLV 02/24/2015 02/24/2015 03/12/2015