Electrical Application Details for App #: M303298
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 212 GRAND STREET MANHATTAN BIN: 1006935     Block: 470   Lot: 29
   
Application Completed and Certified

Filed: 212 GRAND ST Census Tract:   41 Health Area:  6800
BASMNT, 1ST THRU 7TH FLOORS Admin Area:   M - MANHATTAN Inspection Area:   U
NEW YORK, NY 10013 Community Board:   102
DOB Cross Street(s):   MOTT STREET,    ELIZABETH STREET
Status:   C - JOB IS SIGNED OFF 05/04/2011
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/03/2010 6:48 AM
Application Entered:   06/03/2010 Job Start Date:   06/03/2010
Last Change:   05/04/2011 Job End Date:   06/30/2010
Appointment Status:   
Last Inspection By:   DALTON HENLON       On     04/23/2011      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 011465 Licensee Name: LEONID ARLYUK
Firm: 002921 Firm Name: WTG ELECTRIC INC.
Firm Phone: 718-474-3400  Firm Address: 115-14 BEACH CHANNEL DRIVE ROCKAWAY PARK NY 11694 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $827.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: SARAH FONTANET
Owner Business Name: BLDG MANAGEMENT CORP
Authorized Representative:  SARAH FONTANET
Relationship To Owner:   MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  100A, 120/208V, 3P, 4 W
B. 101 Up to 200 AMPS  1  200A, 120/208V, 3P, 4W
C. 201 Up to 600 AMPS  1  600A, 120/208V, 3P, 4W
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  16  4#3AWG THWN
B. Over #2 to 1/0  1  4#3/0 AWG THWN
C. Over 1/0 to 250 MCM  2  4#350AWG THWN
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  15  100A, 1PH, 120/208, 3W
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  100A, 3PH, 120/208, 4W
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001                     
002                     
003                     
004                     
005                     
006                     
007                     
Buildings Total   29  17                    
Total Units : 46 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 15 #4-Wire 2 #10-Wire 0
Existing Meters 17 + New Meters 17 - Removed Meters 17 = Total Meters 17

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 06/03/2010 Notice: 1 - FIRST NOTICE 01/06/2011
Power Issued: 06/03/2010 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  INSTALLATION OF NEW SERVICE IN THE BASEMENT, ELECTRICAL PANELS, AC AND KITCHEN RECEPTACLES IN THE APARTMENTS

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: M303298
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/22/2010 01/06/2011 CCH V G (45) (4) Y
INSPECTION COMMENTS: *CHECK APARTMENT 1ST FLOOR,7TH FLOOR ALSO SUPER'S APARTMENT - ONLY 3 APARTMENTS*........... - SEE VIOLATION DETAILS
 
(2) 04/23/2011 04/28/2011 DAH C R E (55) (0) Y
INSPECTION COMMENTS: NO INSPECTION ON GROUND FLOOR RESTAURANT

OBJECTION FOR APPLICATION #: M303298
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
A) BASEMENT: 100A SER SW NOT BOLTED DOWN..... - 408.36F
RSLV 12/22/2010 12/22/2010 04/23/2011
 
002 (999) OTHER
B) THROUGH-OUT: OUTLET NO BONDING WIRE....... - 250.146
RSLV 12/22/2010 12/22/2010 04/23/2011
 
003 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
THROUGH-OUT: OUTLET IN BEDROOM NOT ARC FAULT
RSLV 12/22/2010 12/22/2010 04/23/2011
 
004 (999) OTHER
C) PANEL: 12 X 3 BX SAME PHASE
RSLV 12/22/2010 12/22/2010 04/23/2011