| BUILDING OVERVIEW |
Are Feeders Being Installed? : Yes |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
1 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
0 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
1 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
(219) |
CONDUIT IS NOT PROPERLY SUPPORTED (TYPE:RMC) BACKYARD |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |
| |
| 002 |
( 33) |
KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX BACK Y: A/H DISCONNECT |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |
| |
| 003 |
(999) |
OTHER BACK Y: L.B UNDER AIR HANDLER HAS NO COVER. 314.25 |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |
| |
| 004 |
( 34) |
KNOCKOUTS ARE NOT CLOSED IN PANEL BOX GROUND: IN BAR NEW PANEL |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |
| |
| 005 |
( 40) |
LOCKNUTS ARE MISSING OR LOOSE GROUND: IN NEW PANEL LOOSE |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |
| |
| 006 |
(999) |
OTHER GROUND: NO TIE BREAKER ON MULTIWIRE CIRCUITS. 210.4 |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |
| |
| 007 |
(999) |
OTHER OUTSIDE: E.G.C.IN A/C DISCONNECT NOT AS PER 250.122 |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |
| |
| 008 |
(219) |
CONDUIT IS NOT PROPERLY SUPPORTED (TYPE:RMC) OUTSIDE: AT A/C COMPRESSORS |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |
| |
| 009 |
( 19) |
DEFECTIVE WIRING IS IN USE OUTSIDE: AT A/C LFMC USED. AM.356.10 |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |
| |
| 010 |
(999) |
OTHER OUTSIDE: LFMC NOT SUPPORTED AS PER 350.30 |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |
| |
| 011 |
(999) |
OTHER OUTSIDE: A/C G.F.C.I. HAS NO IN USE COVER. 406.8 |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |
| |
| 012 |
(999) |
OTHER OUTSIDE: A/C DISCONNECT E.G.C. DOUBLE LUG. 110.14 |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |
| |
| 013 |
( 56) |
ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED OUTSIDE: AT A/C LIQUID TIGHT FITTINGS |
RSLV |
11/17/2014 |
11/17/2014 |
01/05/2015 |