BIS Menu  |  Electrical Inspection Work Order  |  Applications  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B394978
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 259 ALBANY AVENUE BROOKLYN BIN: 3414025     Block: 1376   Lot: 12
   
Application Completed and Certified

Filed: 259 ALBANY AV Census Tract:   339 Health Area:  4900
ALBANY AVENUE Admin Area:   B - BROOKLYN Inspection Area:   G
BROOKLYN, NY 11213 Community Board:   308
Related Job Number:    320977065
DOB Cross Street(s):   STERLING PLACE,    ST JOHNS PLACE
Status:   C - JOB IS SIGNED OFF 10/30/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/29/2015 11:57 AM
Application Entered:   04/29/2015 Job Start Date:   04/29/2015
Last Change:   10/30/2015 Job End Date:   04/29/2017
Appointment Status:   
Last Inspection By:   DAMISO COOTE       On     10/21/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 012323 Licensee Name: SHMUEL AIZIKOVICH
Firm: 002979 Firm Name: OHR CHODOSH ELEC'L CONT I
Firm Phone: 718-338-7726  Firm Address: 1267 UTICA AVENUE BROOKLYN NY 11203 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
7 - HVAC WIRING
L - LIGHTING WORK
Total Fee:  $837.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:   Yes
Job Number:  320977065
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JACOB SCHWIMMER
Owner Business Name: 259 ALBANY REALTY LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  400 AMP
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  10  4/3
B. Over #2 to 1/0  2  3/0
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  10  20-40
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    15  20    15  15         
001    15  20    15  15         
002    15  20    15  15         
003    15  20    15  15         
004    15  20    15  15         
ROF    15  20    15  15         
Buildings Total 90  120    90  90     18           
Total Units : 408 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 11 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 11 - Removed Meters 0 = Total Meters 11

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 04/29/2015 Notice: 1 - FIRST NOTICE 09/14/2015
Power Issued: 04/29/2015 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  RECONSTRUCTION OF ORIGINAL FLOORS AND ADDITIONAL MEZZANINE AND CREATION OF NEW DWELLING UNITS TO TOTAL OF 10 DWELLING UNITS AS SHOWN ON PLANS.

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: B394978
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/25/2015 09/02/2015 CCH A E (115) (7) Y
INSPECTION COMMENTS: FEEDERS TO BLOWERS NO SPLICE BOX
 
(2) 09/11/2015 09/14/2015 CCH A R E (65) (2) Y
INSPECTION COMMENTS: N
 
(3) 10/21/2015 10/30/2015 DIT C R E (50) (0) Y
INSPECTION COMMENTS: NO

OBJECTION FOR APPLICATION #: B394978
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
1ST FL PANEL ON STAIR 240.B2
RSLV 08/25/2015 08/25/2015 09/11/2015
 
002 ( 10) BRANCH CIRCUIT CONDUCTORS ARE NOT PROPER SIZE
ALL STOVE WIRE WITH#12 OUTLET
RSLV 08/25/2015 08/25/2015 09/11/2015
 
003 (999) OTHER
ALL STOVE NEUTRAL BONDED BEHIND 250.24
RSLV 08/25/2015 08/25/2015 09/11/2015
 
004 (999) OTHER
UTILITY BAR NOT ACCESSIBLE 314.29
RSLV 08/25/2015 08/25/2015 09/11/2015
 
005 ( 19) DEFECTIVE WIRING IS IN USE
NO FIXTURES FRONT OF BUILDING
RSLV 08/25/2015 08/25/2015 09/11/2015
 
006 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
GROUNDING TERMINAL IN PANELS NEED 2 SCREWS
RSLV 08/25/2015 08/25/2015 09/11/2015
 
007 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
GROUNDING TERMINAL NOT FROM PLP
RSLV 08/25/2015 08/25/2015 09/11/2015
 
008 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
ALUM SER SW CHASE NIPPLE USE
RSLV 09/11/2015 09/11/2015 10/21/2015
 
009 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
GROUNDING TERMINAL IN PANELS NEED 2 SCREWS
RSLV 09/11/2015 09/11/2015 10/21/2015



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order  |  Applications  |  Back