BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M360610
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 1192 PARK AVENUE MANHATTAN BIN: 1047125     Block: 1505   Lot: 40
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 1192 PARK AV Census Tract:   160.01 Health Area:  2820
APARTMENT 16 B Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10128 Community Board:   108
DOB Cross Street(s):   EAST 93 STREET,    EAST 94 STREET
Status:   C - JOB IS SIGNED OFF 11/28/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  11/08/2014 3:14 PM
Application Entered:   11/08/2014 Job Start Date:   11/10/2014
Last Change:   11/28/2017 Job End Date:   11/10/2015
Appointment Status:   
Last Inspection By:   MODELFINO, CARL C       On     11/28/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010587 Licensee Name: HARRY FRENKEL
Firm: 002697 Firm Name: APOLLO ELECTRIC INC.
Firm Phone: 212-627-2561  Firm Address: 127 WEST 24TH ST,5TH FL STE#A NEW YORK NY 10011 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $359.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: STEVEN FRIBOURG
Owner Business Name: RESIDENCE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1   150 AMP / 3 POLE /208 V
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  4  4 X # 2/0
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  100AMP 3PHASE SUB
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
016  16 B  60  68    48  68     
Buildings Total 60  68    48  68            
Total Units : 246 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 11/08/2014 Notice: 1 - FIRST NOTICE 10/03/2017
Power Issued: 11/08/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: M360610
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/02/2017 10/03/2017 TUR V (55) (2)
INSPECTION COMMENTS: OBJECTIONS ISSUED , AND ONE OBJECTION CORRECTED ON SITE PLUG MOLD BY BUTLERS PANTRY NOW GFCI PROTECTED BY SINK
 
(2) 11/28/2017 11/28/2017 MLF C R (32) (0)
INSPECTION COMMENTS: OBJECTIONS RESOLVED

OBJECTION FOR APPLICATION #: M360610
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(FLOOR: 016)110.3 ELECTRIC TOWEL WARMER MOUNTED IN TUB ENCLOSURE PERMANUFACTURERS NOT TO BE INSTALLED IN THIS LOCATION
RSLV 10/02/2017 10/02/2017 11/28/2017
 
002 (999) OTHER
(FLOOR: 016)210.52 RIGHT AND LEFT OF STOVE COUNTERS HAVE NO OUTLETS AND NOT GFCI
RSLV 10/02/2017 10/02/2017 11/28/2017



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.