BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: B088875
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 1921 AVENUE K BROOKLYN BIN: 3180160     Block: 6721   Lot: 1
   
Application Completed and Certified

Filed: 1921 AV K Census Tract:   762 Health Area:  7310
KBB PUBLIC Admin Area:   B - BROOKLYN Inspection Area:   K
BROOKLYN, NY 11230 Community Board:   314
DOB Cross Street(s):   EAST 19 STREET,    OCEAN AVENUE
Status:   C - JOB IS SIGNED OFF 11/10/1992
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   09/06/1991 Job Start Date:   09/10/1991
Last Change:   09/01/1992 Job End Date:   09/10/1991
Appointment Status:   
Last Inspection By:   O'HARE, R.J.       On     08/27/1992      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 009743 Licensee Name: I COLEMAN
Firm: 000694 Firm Name: INTERCITY ELEC'L CONTR'G
Firm Phone: 718-499-1822  Firm Address: 142 22ND STREET BROOKLYN NY 11232 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $100.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: K.B.B. ASSOC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   9-5 Contact Phone:   252 7180

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 06/29/1992 Notice: 1 - FIRST NOTICE 06/29/1992
Power Issued: 09/06/1991 Response: R - REINSPECTION 07/10/1992

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: B088875
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/04/1991 12/12/1991 LF1 N (10) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 01/08/1992 01/15/1992 RJO N (10) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 03/10/1992 03/17/1992 LF1 N (35) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 04/10/1992 04/29/1992 RJO Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 05/14/1992 05/20/1992 RJO N (5) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 06/19/1992 06/24/1992 LF1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 06/22/1992 06/29/1992 RJO A B (35) (1)
INSPECTION COMMENTS: N/C
 
(8) 07/10/1992 08/04/1992 LF1 N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 08/27/1992 09/01/1992 RJO C R E (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application