Electrical Application Details for App #: Y184037
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 1572 WEBSTER AVENUE BRONX BIN: 2009400     Block: 2897   Lot: 5
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 1600 WEBSTER AV Census Tract:   167 Health Area:  2400
BASEMENT Admin Area:   Y - BRONX Inspection Area:   D
BRONX, NY 10457 Community Board:   203
Special Place Name:   IS 339 (X)
DOB Cross Street(s):   CLAREMONT PARKWAY,    CLAY AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/21/2017 12:39 PM
Application Entered:   08/21/2017 Job Start Date:   08/21/2017
Last Change:   09/29/2025 Job End Date:   12/31/2018
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   JOFFRE PENA       On     10/20/2021      
Field Disp:   V - OBJCTN ISSD: JOB INCOMPLT
Energize Recommendation:  
Objection Disposition:  X - NOT REMOVED

License #: 012531 Licensee Name: LINCOLN A BAKER
Firm: 004351 Firm Name: LABCO ELETRT CONTNG CORP
Firm Phone: 718-525-2355  Firm Address: 124-14 20TH AVENUE COLLEGE POINT NY 11356 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $232.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   W - School
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: NYC SCA NYC SCA
Owner Business Name: NYC SCA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  2  2 SETS 600 MCM
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS            175         
Buildings Total            175           
Total Units : 181 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: C - CALL TO OFFICE 10/20/2021
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: Y184037
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/08/2019 10/08/2019 RID V (89) (2)
INSPECTION COMMENTS: "PLEASE NOTE" THE ELECTRICAL INSTALLATION DOES NOT MEET THE NYC, NEC CODE STANDARD, (1) NO WATER MAIN GROUND PROVIDED AT SEPARATELY DERIVED SYSTEM,(2) NEUTRAL BARS ARE NOT BONDED TO ENCLOSURES(GENERATOR, AND FIRE ALARM DISCONNECT).THIS IS NOT A FINAL INSPECTION||
 
(2) 10/31/2019 10/31/2019 RID H X (31) (0) Y
INSPECTION COMMENTS: "PLEASE NOTE" ALL THE ELECTRICAL VIOLATIONS ARE STILL IN PLACE.
 
(3) 10/20/2021 10/20/2021 JRP V X (36) (2)
INSPECTION COMMENTS: INSPECTION INCOMPLETE

OBJECTION FOR APPLICATION #: Y184037
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
(GROUND FLOOR)GROUND FLOOR OUTSIDE GENERATOR : NO WATER MAIN GROUND PROVIDEDSEPARATELY DERIVED SYSTEM (250.30)
OPEN 10/08/2019 10/08/2019
 
002 (999) OTHER
(GROUND FLOOR)GROUND FLOOR GENERATOR : NEUTRAL BARS IN THE, FIRE ALARM DISCONNECTARE NOT BONDED TO ENCLOSURES(250.26).
OPEN 10/08/2019 10/08/2019
 
003 ( 4) SERVICE IN EXCESS OF 1000KVA HAS NOT BEEN SUBMITTED FOR APPROVAL
(BASEMENT)CONTRACTOR TAP 400 AMP GENERATOR DISCONNECT ON LOAD SIDE OF 4000AMP EQUIPMENT (3500 AMP FUSES) NYC AMENDMENTS 110.2(B)
OPEN 10/20/2021 10/20/2021
 
004 (999) OTHER
(BASEMENT) CONTRACTOR NEED TO FILE PAA FOR ENTIRE SCOPE OF WORK
OPEN 10/20/2021 10/20/2021