Electrical Application Details for App #: B353979
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 451 CLARKSON AVENUE BROOKLYN BIN: 3327711     Block: 4829   Lot: 1
   
Application Completed and Certified

Filed: 449 CLARKSON AV Census Tract:   808 Health Area:  5510
BUILDING C Admin Area:   B - BROOKLYN Inspection Area:   G
BROOKLYN, NY 11203 Community Board:   309
Special Place Name:   KCHC
DOB Cross Street(s):   NEW YORK AVENUE,    EAST 37 STREET
Status:   C - JOB IS SIGNED OFF 03/03/2015
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/12/2012 4:33 PM
Application Entered:   09/12/2012 Job Start Date:   11/05/2012
Last Change:   03/03/2015 Job End Date:   12/31/2013
Appointment Status:   
Last Inspection By:   DALTON HENLON       On     02/18/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010693 Licensee Name: STEVEN M DUFFY
Firm: 003508 Firm Name: ERIN ELEC'L CONTR'G INCOR
Firm Phone: 718-720-3200  Firm Address: 17 RECTOR STREET STATEN ISLAND NY 10310 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
Total Fee:  $415.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   I - Hospital Or Health Facility
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: SEAN KIRINCIC
Owner Business Name: NYCHHC
Authorized Representative:  SEAN KIRINCIC
Relationship To Owner:   MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  3  375
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 03/03/2015 Notice: 1 - FIRST NOTICE 11/03/2014
Power Issued: 03/03/2015 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  PLEASE CONTACT ERIN ELECTRIC DIRECTLY AT 718 720 3200 TO ESCORT INSPECTOR AT FACILITY. ELEVATOR REHABILITATION.

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: B353979
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/27/2014 11/03/2014 CJH V (60) (10) Y
INSPECTION COMMENTS: N
 
(2) 02/18/2015 03/03/2015 DAH C R E (40) (0) Y
INSPECTION COMMENTS: N

OBJECTION FOR APPLICATION #: B353979
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
CELLAR DECAL FOR 480V NOT POSTED 408.60 AMEN
RSLV 10/27/2014 10/27/2014 02/18/2015
 
002 (999) OTHER
CELLAR MOTOR RM DIS SWITCHES GND NOT MINIUM SIZE 250.122
RSLV 10/27/2014 10/27/2014 02/18/2015
 
003 ( 11) FEEDER CONDUCTORS ARE NOT OF PROPER SIZE
CELLAR MOTOR RM FEEDER CONDUCTORS 215.2 A1
RSLV 10/27/2014 10/27/2014 02/18/2015
 
004 (999) OTHER
CELLAR MOTOR RM TRANSFORMER NOT GROUNDED TO WATER MAIN OR BUILDINGSTEEL 250
RSLV 10/27/2014 10/27/2014 02/18/2015
 
005 (999) OTHER
CELLAR MOTOR RM CAR LIGHT DIS SW BLK USED FOR NEU 200.7
RSLV 10/27/2014 10/27/2014 02/18/2015
 
006 (999) OTHER
CELLAR MOTOR RM CAR RECEP DIS SW NEU FUSES 240.22
RSLV 10/27/2014 10/27/2014 02/18/2015
 
007 ( 53) GFCI HAS NOT BEEN PROVIDED
CELLAR MOTOR RM CAR C5 PIT 210.8
RSLV 10/27/2014 10/27/2014 02/18/2015
 
008 (999) OTHER
ALL CAR TAP LIGHTS ON LOAD SIDE OF GFCI 620.22
RSLV 10/27/2014 10/27/2014 02/18/2015
 
009 ( 15) FLEXIBLE CORDS USED AS PERMANENT WIRING METHOD
ALL CAR TOP LIGHTS 400.8
RSLV 10/27/2014 10/27/2014 02/18/2015
 
010 (999) OTHER
CELLAR CAR RECEP OUTLETS DIS SW DOUBLE LUG 110.14
RSLV 10/27/2014 10/27/2014 02/18/2015