NYC Department of Buildings
Electrical Application Details for App #: B283370
NO AHV RECORDS WERE FOUND FOR THIS BIN
Premises: 179 BUFFALO AVENUE BROOKLYN BIN: 3389906     Block: 1363   Lot: 4
   
Application Completed and Certified

Filed: 179 BUFFALO AV Census Tract:   359 Health Area:  5020
ALL Admin Area:   B - BROOKLYN Inspection Area:   H
BROOKLYN, NY 11213 Community Board:   308
Related Job Number:    302198903
DOB Cross Street(s):   ST MARKS AVENUE,    PROSPECT PLACE
Status:   C - JOB IS SIGNED OFF 01/12/2007
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/20/2006 2:45 PM
Application Entered:   09/20/2006 Job Start Date:   09/30/2006
Last Change:   01/12/2007 Job End Date:   09/30/2007
Appointment Status:   
Last Inspection By:   THOMAS, PATRICIA       On     01/02/2007      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 009895 Licensee Name: RUBEN A LOPEZ
Firm: 003333 Firm Name: QUEENSBORO ELEC'L CONTR'G
Firm Phone: 718-803-0200  Firm Address: 12-23A 150TH STREET CORP. WHITESTONE NY 11357 

Work Started or Filed by Others: NO
Work Category:   N - NEW BUILDING Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
8 - BOILER/BURNER WIRING
Total Fee:  $162.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   YES
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: PAUL AMIT
Owner Business Name: GALIT NETWORK, LLC
Authorized Representative:  PAUL AMIT
Relationship To Owner:   PROJECT MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  3  $24.00 3, 100AMP MAIN CB
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  $15.00 ONE SET #2 THHN
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  3  $45.00, 12 CKT SUBPANELS
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 35  45  41  35                
Total Units : 165 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 3 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 3 - Removed Meters 0 = Total Meters 3

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/20/2006 Notice:  
Power Issued: 09/20/2006 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

*NO AHV RECORDS WERE FOUND FOR THIS BIN
INSPECTION FOR APPLICATION #: B283370
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/02/2007 01/08/2007 PAT C E (45) (0) Y
INSPECTION COMMENTS: N