NYC Department of Buildings | ||
Schedule 'A' |
Premises: 1041 FLATBUSH AVENUE BROOKLYN | Job No: 340795483 | |||
BIN: 3117877 Block: 5132 Lot: 80 | Doc No: 01 | Job Type: NB - NEW BUILDING |
Comments | ||||||||
EXISTING / PROPOSED |
FLOORS FRM - TO |
NO. PERS |
LIVE LOAD |
2022/2014/2008 Code? |
OCC GRP |
UNITS |
ZONE USE |
|
EXISTING | SUB - | |||||||
PROPOSED | SUB - | 53 | OG | Y | S-2 | 2B | ||
4 | ||||||||
5B,6 | ||||||||
FUEL STORAGE TANK ROOM, ATTENDANT PARKING GARAGE FOR 52 SPACES (20 SPACES FOR RESIDENTIAL, 28 SPACES FOR COMMERCIAL & 4 SPACES FOR AMBULATORY DIAGNOSTIC), AND BICYCLE PARKING AREA FOR 17 SPACES | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | 82 | 100 | Y | R-1 | 5B | ||
METERS ROOM, COMPACTOR ROOM, LAUNDRY ROOM (3 PERSONS), EXERCISE ROOM (13 PERSONS), STORAGE, EMPLOYEE BREAK ROOM (3 PERSONS), MEETING ROOM (38 PERSONS), BUSINESS CENTER (5 PERSONS) AND OUTDOOR GARDEN AREA (20 PERSONS) | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | 40 | Y | R-1 | 4 | 5A | ||
TRANSIENT HOTEL 4 GUEST ROOMS | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | 55 | 100 | Y | R-1 | 5B | ||
BREAKFAST AREA AND PANTRY. | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | 11 | 100 | Y | R-2 | 2B | ||
OPEN SPACE AT REAR COURT YARD OF 2145SF. ACCESSIBLE TO ALL RESIDENCE ON 8TH & 9TH FLOOR | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 62 | 100 | Y | M | 6 | ||
RETAIL STORE | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 12 | 100 | Y | R-1 | 5B | ||
2B | ||||||||
SHARED LOBBY OF RESIDENTIAL & TRANSIENT HOTEL. | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 100 | Y | S-2 | 5B | |||
ONE LOADING BERTH | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 11 | 100 | Y | B | 4 | ||
AMBULATORY DIAGNOSTIC/HEALTH REHABILITATION | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 40 | Y | R-1 | 13 | 5A | ||
TRANSIENT HOTEL 13 GUEST ROOMS AND OPEN TO BELOW AREA ABOVE LOBBY 30' DIAMETER 704 SF | ||||||||
EXISTING | 003 - | |||||||
PROPOSED | 003 - | 40 | Y | R-1 | 22 | 5A | ||
TRANSIENT HOTEL, 22 GUEST ROOMS | ||||||||
EXISTING | 004 - | |||||||
PROPOSED | 004 - | 40 | Y | R-2 | 22 | 5A | ||
TRANSIENT HOTEL, 22 GUEST ROOMS | ||||||||
EXISTING | 004 - | |||||||
PROPOSED | 004 - | 40 | Y | R-2 | 22 | 5A | ||
TRANSIENT HOTEL, 22 GUEST ROOMS | ||||||||
EXISTING | 005 - | |||||||
PROPOSED | 005 - | 40 | Y | R-2 | 22 | 5A | ||
TRANSIENT HOTEL, 22 GUEST ROOMS | ||||||||
EXISTING | 006 - | |||||||
PROPOSED | 006 - | 40 | Y | R-1 | 22 | 5A | ||
TRANSIENT HOTEL, 22 GUEST ROOMS | ||||||||
EXISTING | 007 - | |||||||
PROPOSED | 007 - | 40 | Y | R-1 | 22 | 5A | ||
TRANSIENT HOTEL, 22 GUEST ROOMS | ||||||||
EXISTING | 008 - 008 | |||||||
PROPOSED | 008 - 008 | 40 | Y | R-2 | 11 | 2A | ||
11 CLASS B APARTMENT HOTELS | ||||||||
EXISTING | 009 - 009 | |||||||
PROPOSED | 009 - 009 | 40 | Y | R-2 | 11 | 2A | ||
11 CLASS B APARTMENT HOTELS | ||||||||
EXISTING | ROF - | |||||||
PROPOSED | ROF - | 100 | Y | R-1 | 5B | |||
2B | ||||||||
MECHANICAL ROOM, ELEVATOR MACHINE ROOM AND EMERGENCY GENERATOR. | ||||||||
C of O Comments: | ||||||||
THESE PREMISES HAVE BEEN DECLARED TO BE SUBJECTED TO THE PROVISIONS OF SECTION 12-10 ZONING RESOLUTION AS TO ZONING LOT OWNERSHIP AS FILED WITH THE CITY REGISTER'S OFFICE UNDER CRFN #2021000369490 & 2021000369489. PARKING RESTRICTIVE DECLARATION HAS BEEN RECORDED UNDER CRFN #2021000374995 AUTOMOBILE PARKING SPACES PROPOSED WILL BE FULLY ATTENDED BY PAID ATTENDENT EMPLOYED BY THE OWNER OR OPERATORS OF SUCH SPACES AND SHALL BE AVAILABLE TO HANDLE THE PARKING 24 HOURS/7DAYS |