NYC Department of Buildings | ||
Schedule 'A' |
Premises: 84 3 AVENUE MANHATTAN | Job No: 121181050 | |||
BIN: 1088780 Block: 556 Lot: 7502 | Doc No: 05 | Job Type: NB - NEW BUILDING |
![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
Comments | ||||||||
EXISTING / PROPOSED |
FLOORS FRM - TO |
NO. PERS |
LIVE LOAD |
2022/2014/2008 Code? |
OCC GRP |
UNITS |
ZONE USE |
|
EXISTING | CEL - | |||||||
PROPOSED | CEL - | 26 | OG | Y | M | 6 | ||
CHANGE | ||||||||
COMMERCIAL STORAGE (INCIDENTAL USE TO COMMERCIAL) | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | OG | Y | R-2 | 2 | |||
ADD | ||||||||
MECHANICAL ROOMS, REFUSE ROOM (INCIDENTAL USE TO RESIDENTIAL) | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | OG | Y | R-2 | 2 | |||
ADD | ||||||||
(2) RESIDENTIAL STORAGES (INCIDENTAL USE TO RESIDENTIAL) | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | OG | Y | R-2 | 2 | |||
ADD | ||||||||
BICYCLE STORAGE FOR 60 SPACES (482 SQ. FT.) INCIDENTAL USE TO RESIENTIAL | ||||||||
EXISTING | CEL - | |||||||
PROPOSED | CEL - | OG | Y | R-2 | 2 | |||
ADD | ||||||||
SUPER'S OFFICE (INCIDENTAL USE TO RESIDENTIAL) | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 100 | Y | R-2 | 2 | |||
CHANGE | ||||||||
RESIDENTIAL LOBBY | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 349 | 100 | Y | M | 6 | ||
CHANGE | ||||||||
COMMERCIAL SPACE | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 100 | Y | R-2 | 2 | |||
CHANGE | ||||||||
BICYCLE STORAGE FOR 45 SPACES (496 SQ. FT.) | ||||||||
EXISTING | 001 - 001 | |||||||
PROPOSED | 001 - 001 | 100 | Y | M | 6 | |||
ADD | ||||||||
COMMERCIAL MECHANICAL ROOM | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 400 | Y | R-2 | 2 | |||
CHANGE | ||||||||
FITNESS ROOM (INCIDENTAL USE TO RESIDENTIAL) | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 40 | Y | A-3 | 2 | |||
CHANGE | ||||||||
RECREATION SPACE | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 40 | Y | R-2 | 2 | |||
ADD | ||||||||
LAUNDRY ROOM (INCIDENTAL USE TO RESIDENTIAL) | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 40 | Y | R-2 | 2 | |||
ADD | ||||||||
(4) PRIVATE TERRACES | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 40 | Y | R-2 | 2 | |||
ADD | ||||||||
PUBLIC TERRACE (ACCESSORY USE TO RESIDENTIAL) | ||||||||
EXISTING | 002 - 002 | |||||||
PROPOSED | 002 - 002 | 40 | Y | R-2 | 7 | 2 | ||
ADD | ||||||||
7 CLASS "A" APARTMENTS/REFUSE ROOM | ||||||||
EXISTING | 003 - 008 | |||||||
PROPOSED | 003 - 008 | 40 | Y | R-2 | 13 | 2 | ||
CHANGE | ||||||||
13 CLASS "A" APARTMENTS/REFUSE ROOM ON EACH FLOOR | ||||||||
EXISTING | 009 - 009 | |||||||
PROPOSED | 009 - 009 | 40 | Y | R-2 | 2 | |||
CHANGE | ||||||||
BOILER ROOM & MECHANICAL ROOMS (INCIDENTAL USE TO RESIDENTIAL) | ||||||||
EXISTING | ROF - | |||||||
PROPOSED | ROF - | 100 | Y | R-2 | 2 | |||
CHANGE | ||||||||
POOL (ACCESSORY USE TO RESIDENTIAL) | ||||||||
C of O Comments: | ||||||||
ALL STREET TRESS SHALL BE PLANTED, MAINTAINED AND REPLACES AS NECESSARY WITH THE APPROVAL OF AND IN ACCORDANCE WITH THE STANDARDS OF THE DEPARTMENT OF PARKS AND RECREATION AND DEPARTMENT OF TRANSPORTATION AS PER ZR 28-12. ALL RELATED FACILITIES AND AMENITIES REQUIRE PURSUANT OF THE QUALITY HOUSING PROGRAM SHALL NOT BE REMOVED TOTAL: 85 CLASS "A" APARTMENTS |